Electrical Permit — 3400 SPRUCE ST
Electrical
Not listed
Shelly Electric Co Inc
Trs Univ Of Penn
Philadelphia County
Work Description
Addition and/or Alteration - FIRE ALARM: (9) Duct Smoke Detector; (9) Damper module; (9) Rem Test Station & Key switch; (9) Relay. As per 2016 NFPA 72. ELECTRICAL: (2) Connect to existing trough; (2) Enclosed CB: (1) 250/175; 250/200; (3) Integral Panel in AHU-1301; (1) Connect to existing panel LEQ15F 100/3; (2) Connect new pumps to existing MCC (2) 100/3. Disconnect switches: (1) 20/1; (1) 35/1; (1) 40/1; (6) 20/3; (1) 40/3; (1) 60/3. Motor starters: (2) 20/3; (1) 60/3. Motor connections: (3) 20/1; (6) 20/3; (2) 40/3; (2) 60/3; (5) 70/3; (1) 90/3; (1) 100/2. (11) Lighting Fixtures ; (1) Crane Conn 20/1; (2) Receptacles. As per 2017 NEC.
Other permits at this address
8 other permits at 3400 SPRUCE ST. Electrical, plumbing, and HVAC on the same property usually share a general contractor.
Addition and/or Alteration - FIRE ALARM: (3) Strobe; (2) Smoke Detector. As per NFPA 72. ELECTRICAL: (3) Connect to existing panels – add new breakers: (1) 70/3; (1) 30/2; (4) 20/2; (15) 20/1. New pan...
Addition and/or Alteration - From an existing 200-amp electrical panel, install a 60-amp feeder to supply one (1) 60-amp subpanel, including all required overcurrent protection, grounding, bonding, an...
Addition and/or Alteration - Install Power, Lighting, and fire alarm per approved plans. NEC 2017
Addition and/or Alterations - DEMOLITION AND INSTALLATION OF MECHANICAL EQUIPMENT IN AN EXISTING HOSPITAL BUILDING (FOUNDERS BUILDING) INCLUDING ASSOCIATED PIPING, VALVES, INSULATION AND SUPPORTS AS P...
Addition and/or Alterations - EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construct...
Addition and/or Alteration - FOR LEVEL II ALTERATIONS TO THE 5TH FLOOR OF THE FOUNDERS BUILDING IN AN EXISTING STRUCTURE. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNI...
Addition and/or Alteration - FOR A LEVEL II INTERIOR ALTERATIONS (NO CHANGE IN OCCUPANCY ) TO A PORTION OF AN EXISTING HOSPITAL. WORK TO INCLUDE STRUCTURAL UPGRADE FOR MEP INSTALLATION AS PER APPROVED...
Alterations - Refresh, to Dulles 6th floor. Fixtures, traps and faucets
More Electrical permits in Philadelphia
Addition and/or Alteration - 200 Amp Service, Meter, Panel & Rewire Throughout.
New Construction - Electrical Permit for combo RP-2025-007676 EZELEC - NEW SERVICE ELECTRICAL WIRING/DEVICES THROUGHOUT AS PER 2017 NEC. Deviations from the EZ Permit standards require submission of c...
Addition and/or Alteration - Electrical Permit for combo CP-2025-004648
Addition and/or Alteration - Install a 100 - amp service, receptacles and switches and replace receptacles and switches. Fishing wires through walls only as per 2017 NEC.
New Construction - Install New 600amp Service With 16 Meters, Complete Electrical Fit Out Of 15 Unit Apt Building New Fire Alarm System. According to NFPA 72, 2016 & The Philadelphia Fire Code, 2018....