Philadelphia, PA
Philadelphia · PA
Philadelphia · PA
Addition and/or Alteration - Install 159 LA-101 Downlights 6 LA-102 Undercabinet Lights 17 LA-103 4" Surface mount LED Lights 9 LA-103A 2" surface mount linear lights 4 LA-104 LED Wall Sconces 6 1' LED pendants 8 LED vanity lights-bathroom 4 LED vanity lights-common area corridors 21 Dimmer switches 127 Switches, 130 Receptacles Throughout 40 GFIs Throughout 14 V/D Outlets 26 Smoke Alarms Dedicated Circuits for: 5 Washer 5 Dryer 5 Refrigerator 5 Garbage Disposal 5 Range 5 Range Hood 5 Dishwasher 5 Structured Media Cabinet 9 AHUs AHU-200 FS 2-1 FS2-2 EF 200 Door Entry Control Panel Fire Alarm Control Panel HP-2 • 100A(120-240V/Single Phase/MCB/30 circuit panels for units 201,202,203,204,205 • Provide Power Feed(100A/Single Phase- 3#1+1#8G) MC wire from panel A2A in second Floor Closet to unit 201 • Provide Power Feed(100A/Single Phase- 3#1+1#8G) MC wire from panel A2B in 2nd floor closet to unit 205 on 2nd Floor • Provide power feed(200A/Single Phase-3#3/0 +1#6G) from basement switch gear #3 to 2nd floor closet for panel A2B • Provide Power Feed(100A/Single Phase- 3#1+1#8G) MC wire from switchgear 3 in basement to 2nd floor closet • A 400A/4P/Fused 225A disconnect • Provide power feed (5#4/O+1#2 G) from existing wire way to new disconnect • Provide power feed (5#4/O+1#2 G) from new disconnect to transformer T4A • Provide power feed from transformer to PNL PH1A • New PH1A panel (250A/3 Phase/4W/MCB/30 circuits) • F&I 1.25” EMT pipe from the communication closet to each unit • F&I a CAT 6 & RG 6 coax wire from LV panel/box to 10 TV locations • F&I 5- LV Panel boxes • Intercept and extend existing second floor tenant branch circuit to new A2C panel in 2nd floor closet Demo Work: • Basement: o Demolish and remove existing 4 Pole bar to allow for 2-200A/2 pole/ fused disconnect switches o Demolish and remove existing 3 pole bar to allow for 2 fused disconnects (100A) o Disconnect and remove power feed to generator transfer switch • Roof o Demo existing transformer power feed from existing wireway
3 other permits at Philadelphia, PA. Electrical, plumbing and HVAC on one property often share a GC, so follow the paper trail.
New Construction - install 200a, 1ph, 120/240v main service. Install all wiring throughout single family., Install recessed lighting throughout, Install low voltage wiring for tv
Addition and/or alteration - replace existing conventional facp which is end-of-life and is no longer supported by manufacturer, including annunciator and initiating devices, to be…