502 Wood St in Philadelphia, PA has a electrical permit (#EP-2026-002804) filed Saturday, May 16, 2026 by Barry Hassan. Status: issued.
Philadelphia · PA · 19106
What is permit #EP-2026-002804 at 502 Wood St, Philadelphia, PA?
502 Wood St in Philadelphia, PA has a electrical permit (#EP-2026-002804) filed Saturday, May 16, 2026 by Barry Hassan. Status: issued.
New Construction - Scope of Work: Provide all labor, materials, equipment, and supervision necessary to supply and install the complete electrical system in accordance with the Owner’s Scope of Work dated Wednesday, December 3, 2025, the referenced construction documents, the National Electrical Code, and all applicable local codes and authorities having jurisdiction. Included Scope: • PECO temporary service application and associated fees • Temporary power outlets on all floors • Temporary lighting in stairwells and hallways to maintain a safe, well-lit site • Complete PECO vault room scope including coring, grounding, lighting, receptacles per PECO specs, cable ladder, secondary wiring from transformers to main service and house service • Supply and installation of breakers and panelboards for all apartment units • Electrical services from the main electrical room to individual apartments • Exit and emergency lighting, including 5” LED surface fixtures in apartment hallways and stairwells (excluding basement and garage areas) • Complete fire alarm wiring and system installation per approved drawings • RG6 cabling from apartment units to telecommunications closet on same floor • Electrical permit acquisition and electrical inspection fees Exclusions • Decorative lighting fixtures of any type • Basement and garage normal and emergency lighting • (2) 1200A main disconnects and metering for the 74 apartment units • House CT cabinet, house main panel, and breakers for house panels • Media boxes within dwelling units • Micro-duct conduit and wiring to dwelling units • Cable company primary infrastructure and terminations ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC, 2016 NFPA-72, 2018 PHILA FIRE CODE.
2 other permits at 502 Wood St. Electrical, plumbing and HVAC on one property often share a GC, so follow the paper trail.
Addition and/or Alteration - Installation of 5.280 kW Roof Mount Solar System 16 Solar Panels 16 IQ8MC Microinverters .ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NE…
Addition and/or Alteration - Perform an interior fit-out of the existing cellar, ground floor, mezzanine, and roof levels for a banking facility. Work includes complete electrical…