14,805 permits · CA · Los Angeles
New elevetor connecting first and second floor.
Add sill plate anchor bolts and plywood to cripple walls (if existing) per LA City Standard Plan #1; no foundation replacement (Earthquake hazard reduction per Chapter 92 of the Los Angeles Building C...
Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 6 Squares. Class A roof covering is required within Very High Fire Hazard Severit...
Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft.over existing solid sheathing __18____Squares. Class A roof covering is required withinVery High Fire Hazard Sev...
Earthquake retrofit anchor bolt installment with engineer's details.
Supplemental to 14010-30000-03519 Add eaves to existing trellis and add solid cover. Convert existing wine room to storage room. Add glass doors and windows separating the garage and lobby on the base...
Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 21 Squares. Class A roof covering is required within Very High Fire Hazard Severi...
1 window(s). Window and door change-out (same size & type) for residential buildings. Dual glazing, labeled and certified by National Fenestration Rating Council (NFRC), is required for doors and wind...
Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over new solid sheathing 10 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zo...
Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 2 Squares. Class A roof covering is required within Very High Fire Hazard Severit...
Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 21 Squares. Class A roof covering is required within Very High Fire Hazard Severi...
Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 41 Squares. Class A roof covering is required within Very High Fire Hazard Severi...
(1) Kitchen/ (4) bathroom remodel for residential buildings (no structural changes). MEPs Included
bathroom remodel for residential buildings (no structural changes)ELECTRICAL AND HVAC INCLUDED
Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 25 Squares. Class A roof covering is required within Very High Fire Hazard Severi...
Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 24 Squares. Class A roof covering is required within Very High Fire Hazard Severi...
Supplemental permit to 24010-20000-05060 to revise height elevation of ADU.
CONVERT (E) CRAWL SPACE INTO HABITABLE AREA AND JADU, ADDITION TO THE GROUND AND FIRST FLOOR LEVEL TO BECOME A ONE STORY SFD W/ ATTACHED BASEMENT/JADU PER GC&66323(a)(1) and 66333.
GRADING FOR NEW AFFORDABLE HOUSING APARTMENT BUILDING.CalOSHA permit must be obtained before construction is commenced
Grading permit3 of 3