Building Permits in ZIP 19107
Philadelphia, PA — 209 permits filed recently
209 permits
Addition and/or Alteration - FOR LEVEL II INTERIOR ALTERATIONS WITHOUT A CHANGE TO EXISTING GROUP M OCCUPANCY CLASSIFICATION WITHIN TENANT SPACE #C220. EXISTING BUILDING IS SPRINKLERED. ALL WORK TO BE...
Addition and/or Alteration - FOR EXTERIOR REPAIRS TO INCLUDE MASONRY REPAIR AND WINDOW REPLACEMENTS AS PER APPROVED PLANS.
Addition and/or Alteration - Install new Fire alarm panel, speakers and strobes .PER APPROVED DRAWINGS-2017 NEC,2016 NFPA-72.
EZ Roof Covering Replacement - **Existing Philadelphia Historic Property** For repair / replacement of roof covering(s) on existing roof(s) in accordance with the attached EZ Permit Re-Roofing Standar...
Addition and/or Alterations - INSTALLATION OF TWO (2) TYPE 1 COMMERCIAL KITCHEN EXHAUST HOODS CONNECTED TO EXISTING EXHAUST DUCTWORK AND FAN. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE W...
Shelter/Platform - - Erection of a sidewalk shelter platform as per Engineered Plans. Streets Department permit is required for sidewalk closure prior to the start work.
Addition and/or Alteration - FOR LEVEL II ALTERATIONS TO AN EXISTING COMMERCIAL BUILDING (RESTAURANT). ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIB...
Addition and/or Alteration - From an existing 400-amp main circuit breaker panel, install a feeder to supply one (1) 200-amp subpanel for the coffee shop. Provide all associated wiring, terminations,...
Change of Use - Eating and Drinking Establishments - Sit-Down Restaurant
Addition and/or Alteration - Install video projectors, monitors, PTZ cameras, ceiling mics, speakers, rally bar for tele conf, room schedulers on 5th and 6th floor for Stateside new offices. work is i...
Rough-In - Rough-In Permit for EP-2026-001928
Signs (Accessory / Non-Accessory) - FOR THE INSTALLATION OF ONE (1) STATICALLY ILLUMINATED WALL SIGN ON AN AWNING. SIZE AND LOCATION AS SHOWN IN APPLICATION/PLANS
Addition and/or Alterations - EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construct...
Addition and/or Alterations - FOR THE INSTALLATION OF HVAC APPLIANCES, GRDs, AND ASSOCIATED DUCTWORK AND FUEL GAS PIPING. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IMC AND PHC...
Alterations - CONVERSTION OF OFFICE BUILDING TO 622 UNIT APARTMENT BUILDING ON 6TH THROUGH TWELTH FLOORS. INTERIOR INSTALLATION OF DRAINAGE, WASTE, VENT, AND WATER SUPPLY FOR LISTED FIXTURES. ALL MATE...
Addition and/or Alterations - FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FO...
Alterations - Plumbing per plans installed to the 2018 Philadelphia Plumbing Code section 919. All piping must be metallic
Addition and/or Alteration - FOR LEVEL II ALTERATIONS (WITH NO CHANGE IN OCCUPANCY) AT FIRST FLOOR OF EXISTING BUILDING. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND PLUMBING WORK.
Addition and/or Alteration - Replace existing lighting with new energy efficient LED lighting. Replace existing lighting control with new. Connect new HVAC equipment to existing circuits
Alterations - REPAIR/REPLACE 3/4" WATER DISTRIBUTION PIPE CURB TO FOUNDATION WALL.