Repair/replacement affecting 1 systems : 2 rooftop packaged unit(rtu 1 & 5 lennox, lgt120h5eh-y, rooftop) 3 rooftop packaged unit(rtu 2,3,4 lennox, lgm060u5ex-y, rooftop) 1 rooftop packaged unit(rtu 6...
Limited repair (25% or less) for wood porch (open) (quantity: 1, location: front of building). landing: 45 square feet. landing not more than 6 feet above ground.
Repair/replacement affecting 1 systems : 1 rooftop packaged unit(lennox unit, model # lgm150u5eh-y, rooftop) 1 rooftop packaged unit(lennox unit, model # lgm120u5eh-y, rooftop) 1 rooftop packaged unit...
Self cert 2019 cbc - repair existing rear 2 story steel porch to an existing 2 story residential masonry building.
Repair or in-kind replacement of 17 plumbing fixtures as described in permit application. repair or in-kind replacement of hot water heater(s). includes repair or replacment of plumbing piping. locati...
Line voltage electrical work. add 1 circuits to existing 200 amp service disconnecting means. receptacle outlets: 1 . lighting outlets: 0. specific location: basement, detached garage and outside.
Install solar panels on roof of principal building. roof type: low-sloped (<2:12). inverter output: 0.29 kw. array output: 0.01584 kw. location: install solar panels on roof. icc distributed generatio...
Install solar panels on roof of principal building. roof type: sloped (2:12 to 5:12). inverter output: 0.29 kw. array output: 0.00396 kw. location: install solar panels on roof. icc distributed genera...
Line voltage electrical work. repair or alter devices on existing circuits. receptacle outlets: 4 . lighting outlets: 4. specific location: 1st floor.
Spr 2019 cbc: new 2-story+ basement frame building (3 dwelling units)new steel front stairs. new steel rear 2-story porch. new 3 space parking pad. mechanical, electrical and plumbing per plans.**cert...
Spr 2019 cbc: new 2-story+ basement frame building (3 dwelling units)new steel front stairs. new steel rear 2-story porch. new 3 space parking pad.mechanical, electrical and plumbing per plans.**certi...
Spr 2019 cbc: new 2-story+ basement frame building (3 dwelling units)new steel front stairs. new steel rear 2-story porch. new 3 space parking pad. mechanical, electrical and plumbing per plans.**cert...
Line voltage electrical work. new permanent 200 amp service disconnecting means with 1 circuits. receptacle outlets: 5 . lighting outlets: 5. specific location: unit 1.
Repair or in-kind replacement of 4 plumbing fixtures as described in permit application. includes repair or replacment of plumbing piping. locations: 1 residential unit(s), 0 non-residential unit(s),...
Tuckpointing and unit masonry repair / replacement: 3000 sq. ft., lintel qty. 0, max. length 0. parapet rebuilding: 25 sq. ft. location: east wall and parapets.
Tuckpointing and unit masonry repair / replacement: 250 sq. ft., lintel qty. 0, max. length 0. location: north and east facade.
New detached wood frame garage. dimensions and setbacks per application. building outside dimensions: 24'-0' ' x20'-0' '. gable roof height to peak: 15'-0' '.
Full rebuild (same as existing) for wood porch (open) (quantity: 1, location: rear of building).
Limited repair (25% or less) for wood porch (open) (quantity: 1, location: front of building). landing: 50 square feet. landing not more than 6 feet above ground.
Line voltage electrical work. new permanent 200 amp service disconnecting means with 24 circuits. receptacle outlets: 1 . lighting outlets: 1. specific location: basement.