Renovation Permits in Chicago, Illinois
861 renovation permits filed recently
861 permits
Spr 2019 crbc. repair fire damage, deconvert from 3 dwelling unit to a single family residence, interior alterations and an 2nd floor addition to an existing 1 1/2 story frame building single family r...
Tuckpointing and unit masonry repair / replacement: 50 sq. ft., lintel qty. 6, max. length 5. parapet rebuilding: 350 sq. ft. location: west elevation.
Tuckpointing and unit masonry repair / replacement: 450 sq. ft., lintel qty. 0, max. length 1. location: damage exterior wall.
Tuckpointing and unit masonry repair / replacement: 4000 sq. ft., lintel qty. 0, max. length 0. location: building exterior.
Tuckpointing and unit masonry repair / replacement: 500 sq. ft., lintel qty. 0, max. length 0. location: exterior south and east sides of building..
Tuckpointing and unit masonry repair / replacement: 500 sq. ft., lintel qty. 0, max. length 0. parapet rebuilding: 75 sq. ft. location: north firewalls, south parapet wall.
Tuckpointing and unit masonry repair / replacement: 1000 sq. ft., lintel qty. 10, max. length 6. location: north, south, and west (front) facades.
Spr 2019 cbrc - proposed rear 2nd story addition, rear north side 6' wood fence, rear yard trellis, and interior/exterior alterations for an existing 2 story sfr, per plans. variation #477-24-z to red...
Spr 2019 cbrc: front facade repair to an existing 2-story with basement 6du masonry building (occupancy group r-2; construction type iiia)
Tuckpointing and unit masonry repair / replacement: 900 sq. ft., lintel qty. 0, max. length 0. location: east elevation.
Replace 2 two story open wood porches, and miscellaneous repairs, same as existing to existing 2 dwelling unit two story building.
Spr 2019 cbrc - interior renovation of existing dwelling unit #18c per plans in high-rise residential building
Spr 2019 cbrc: conversion from 2 d.u. to 3 d.u. and interior renovation of existing d.u.'s in an existing 2 story plus basement, brick residential building. existing r-5 occupancy, no change in occupa...
Tuckpointing and unit masonry repair / replacement: 70 sq. ft., lintel qty. 0, max. length 0. location: south elevation.
Concrete masonry repair / replacemnt: 600sq. ft., excavation = . location: parking garage.
Spr 2019 cbrc - interior alterations to existing condo unit #5405 in an existing 66 story 107 condo unit building.(occupancy r2 classification) ( type ia construction)
Spr 2019 cbrc: structural repairs to the existing sub-basement floor structure at city hall (121 n lasalle st) to restore structural capacity of an existing steel beam as per plans. work includes inst...
Tuckpointing and unit masonry repair / replacement: 300 sq. ft., lintel qty. 0, max. length 0. location: south, north elevation, parapet wall tuck point.
Fire alarm: repair existing system. affects: 0 dwelling units; 0 non-residential units. high-rise building: yes. voice communication: yes. special locking: no. monitoring type: supervising station . s...
Repair lintel and masonry to an existing 1 story commercial building