Addition and/or Alteration - Connect (1) new sign to existing sign circuit. No new wiring or building permit involved. General permit #GP-225-009229
Addition and/or Alteration - 200A Service Replacement 200A Grounding & Bonding System 200A Meter Socket 40CKT Main Breaker Panel PVC Conduit Protection on exterior
Addition and/or Alteration - Furnish and install a fire alarm system for a mixed-use building. Work includes installation of fire alarm control equipment, initiating devices, notif…
New Construction - Install 250 amp service equipment with grounding. Wiring throughout the building. Install light fixtures, outlets, switches, smoke alarms, exit signs, and emerge…
Addition and/or Alteration - Replace 100 AMP service ad panel Install dedicated lines using wire mold (fishing wires) Replace switches, outlets and fixtures Replace basement fixtur…
Unlimited owner reveals + same-day permits
Pro lifts the 10/month cap, drops the 7-day freshness delay, and lets you export any search to CSV. $79/mo for the first 100 subscribers.
Addition and/or Alteration - Install lighting and receptacles for nail salon. per approved drawings-2017 NEC
Addition and/or alteration - wiring to include receptacle, switches, lighting, gfci, smoke detectors, disconnects, and appliances connecting to existing 100 amp panel and services.…
Addition and/or Alteration - ***NEC 2017 FISHING ONLY*** Partial Rewire: Front Bedroom Rewire w/ 3x outlets Middle Bedroom Rewire w/ 3x outlets Replace basic fixture Replace laundr…
Addition and/or Alteration - Interior wiring and 200 amp service upgrade.
Addition and/or Alteration - 100 AMP service, 30 space panel, replace fixtures, outlets, smoke/co detectors, GFCI's and run four 20 AMP lines as per PHDC Trade Work Order #219537.
Addition and/or Alteration - Perform tenant fit-out of an existing space for a new veterinary clinic. Work includes removal and relocation of two (2) existing subpanels to new loca…
Addition and/or Alteration - new 200 amp electrical device to building
New Construction - Electrical Permit for combo RP-2024-012752
Addition and/or Alteration - relocate lights, Light switch, and receptacles in the bathrooms 149 units all work per approved plans. ***NO FIRE ALARM ON THIS PERMIT***
Addition and/or Alteration - Install 200 amps service, panel, switches, receptacles, lights fixtures, rewire entire property as per NEC code 2017
Addition and/or Alteration - 100 amp service, 2 gang meter, rewire--fishing
Addition and/or Alteration - Rewire as per Nec 2017 Smokes and Co detector 20 recess light Install arch faults as per nec 2017 Replace 100amp panel inkind
New construction - intall 400a main service equipment (to be directly buried under at least 2" of concrete and positioned in rear of property)and sub feeders for 3 apartments and l…
Addition and/or Alteration - Rewire as per Nec 2017 Smokes and Co detector 20 recess lights Install arch faults as per nec 2017 Replace 100 amp panel in kind
Addition and/or Alteration - Furnish and install fire alarm as per drawings, 2 duplex, 2 GFI's, 4 dedicated, 2 wall feeds, 2 floor cores, 1 L-1, 2 L-2, 5 L-3, 27 feet of L-4, 2 exi…