Renovation Permits in Minneapolis, Minnesota
479 renovation permits filed recently
479 permits
******* Basement bedroom height does not meet the 6'4" per building inspector, 4-14-2026********** BASEMENT FLOOR FINISHED OF EXISTING SINGLE FAMILY HOUSE. AAJ (PROJECT DOX PLANS) - INSTALL NEW PARTIT...
(DMH-Pdox) INSTALL 2 BASEMENT EGRESS WINDOW & WELL TO FRONT & REAR YARDS OF SFD. - 2020 MNSBC FINISH FOR 2 BASEMENT BEDROOMS, BATHROOM, FAMILY ROOM. INSTALL CEMENT BACKER BOARD FOR CERAMIC TILE AT TUB...
Add hardie panel to portion of exterior -ACW certificate of occupancy required: no special inspections required: no 2020 MSBC
SUITE #45. CHANGE OF OWNERSHIP. NO CONSTRUCTION. INSPECTION ONLY. (JJL) PREVIOUS PERMIT BLDG880910 (DMH - ProjectDox) INTERAGENCY REQUEST FOR BUILDING INSPECTION FOR STATE LICENSED FACILITY TO OFFICE...
Bathroom remodel -ACW certificate of occupancy required: no special inspections required: no const type: 1A occupancy: B 2020 MSBC sprinklered: yes architect: Blewitt, Matthew John
Remove and replace 2x Double Casement Windows & 1x Single Casement Window in the Living Room in Existing Openings and Same Size-No Alterations to opening.
(DMH - Pdox) INSTALLATION OF BASEMENT EGRESS WINDOW & WELL AT SIDE YARD OF SFD. THIS PERMIT IS NOT APPROVAL OF ANY SLEEPING ROOMS, IMPROVEMENTS MADE WITHOUT A PERMIT, OR WORK OTHER THAN DESCRIBED. A S...
Install one new egress window with well on basement floor east elevation wall of existing single family house. aaj (project dox plan). also, - update smoke detector (sd) and carbon monoxide (co) alarm...
Remodel of dental clinic -ACW certificate of occupancy required: no special inspections required: no const type: VB occupancy: B 2020 MSBC occupant load: 27 Tenant: Children's Dental Services Floor(s)...
ANTENNAS ON BUILDING Rated Exit Stair Enclosures are not allowed as a raceway for any of the installation 2020 Minnesota State Building Code
Water Damage Repair - Office and Common Areas WALLS SEPARATING DWELLING UNITS IN THE SAME BUILDING, AND WALLS SEPARATING DWELLING UNITS FROM OTHER OCCUPANCIES CONTIGUOUS TO THEM IN THE SAME BUILDING S...
New dispensary in existing building -ACW certificate of occupancy required: no special inspections required: no const type: VB occupancy: M 2020 MSBC occupant load: 17 sprinklered: no 20% accessibilit...
(DMH-Pdox) REMODEL TO KITCHEN, MUDROOM, LAUNDRY AND HALF BATH LOCATIONS IN SFD. - 2020 MNSBC DEMO SELECT PARTITION WALLS AND REFRAME IN NEW LOCATIONS. MAKE PASS-THRU KITCHEN TO DINING. NO WINDOW REPLA...
New siding on portions of building -ACW certificate of occupancy required: no special inspections required: no 2020 MSBC windows with sill heights less than 36 inches above the floor shall be equipped...
We are repairing the top 1-foot of masonry on the chimney. A new Kasota stone crown & reinforced concrete cap will be installed.
Remove/replace 3x windows, No frame alteration
REPAIR RETAINING WALL 2020 MSBC engineer: 47088 - Felton, Jarrod Jackson
Interior Remodel Building Code: 2020 MNSBC/2018 IRC Energy Code: MINNESOTA RULES CHAPTER 1322 Windows installed under this permit shall meet the requirements of the current Minnesota State Residential...
(DMH-Pdox) APPROX 21' X 12' 2ND LEVEL WEST ADDITION TO SFD FOR NEW BATHROOM AND OFFICE. -2020 MNSBC MAKE STRUCTURAL IMPROVEMENTS WITH NEW LVL & STEEL BEAMS, FLOOR JOISTS AND CONCRETE PAD FOOTING PER E...
Replace tub w/ walk-in shower - Unit 101 Building Code: 2020 MNSBC/2018 IRC Energy Code: MINNESOTA RULES CHAPTER 1322 WALLS SEPARATING DWELLING UNITS IN THE SAME BUILDING, AND WALLS SEPARATING DWELLIN...