Building Permits in ZIP 11373
Queens, NY — 300 permits filed recently
300 permits
Temporary cantilevered platform, needle beam for adjacent overhead protection
Install temporary construction fence as shown on plan @ proposed construction site.
Carrier: VZW. Install (4) antenna sectors on the roof (16 antennas, 16 RRH, 4 OVP & 2 GPS). Install (3) cabinets on a new equipment platform on the roof. In conformance with TPPN #5/98. No change in u...
Install temporary dry standpipe system during construction as per plans filed in conjunction with nb job# 421639980. no change in use,egress and occupancy.
Installation of support of excavation and foundation work as per the plans filed herewith. no change in use, occupancy or egress.
Proposed a new 3-story residence for 3-dwelling units. obtain a new certificate of occupancy.
Installation of suspended scaffold for facade repair & inspection.
Proposed installation of heavy duty sidewalk shed as per plans. live load 300 lbs per square feet. sidewalk shed shall comply with chapter #33 of the nyc building code. no change in use, occupancy, or...
Investigative facade inpection with caulking and temporary waterproofing of fire stair shaft t floors 002-020
Proposed installation of heavy duty sidewalk shed as per plans. live load 300 lbs per square feet. sidewalk shed shall comply with chapter #33 of the nyc building code. no change in use, occupancy, or...
Installation of suspended scaffold for facade repair & inspection.
This filing supersedes prior bis job #421083954 for fire and water damage repairs. interior repairs limited to damaged areas at front dwelling units only on cellar, first, second and third floors. no...
Herewith filing new partial sprinkler system installation. Filed in conjunction with Alt 1- BIS application# 410021854. No change of use, egress, or occupancy.
Herewith filing new partial sprinkler system installation. Filed in conjunction with Alt 1- BIS application# 410021854. No change of use, egress, or occupancy.
This filing supersedes prior bis job #421083954 for fire and water damage repairs. interior repairs limited to damaged areas at front dwelling units only on cellar, first, second and third floors. no...
installing construction fence
File to convert existing one-family building to two-family building with construction work as per plan. plumbing work to be filed separately. obtain new certificate of occupancy.
File to convert existing one-family building to two-family building with construction work as per plan. plumbing work to be filed separately. obtain new certificate of occupancy.
installing construction fence
Facade repair including lintel replacment, parapet wall replacement and brick repointing as per plan. no change in use, egress or occupancy.